Then the glass plate is pushed over the edge of the cup to remove any excess material. The resulting negative pressure keeps the material in the cup. Viscometers are instruments used to measure viscosity, the internal friction of the layers of a liquid in motion. If you now pull the glass plate horizontally from the beaker, you have to activate the stopwatch. An example is the slower flow of syrup from a container syrup is more viscous than water. As soon as the outflowing stream breaks for the first time, you have to stop the time and note it down. When using a flow cup, it is particularly important to ensure that it is cleaned thoroughly after each measurement, as residues in the nozzle and cup can falsify the further results. Cast Stainless Steel body, available in sizes: 3/8 to 2 1/2. Even deep or many scratches in the cup can lead to measurement uncertainties in the result, since the removed material changes the volume of the cup and thus no longer complies with the specified DIN standard.Gemu's 554 Angle Seat Globe Valve is a normally closed, pneumatically operated 2/2 valve featuring a plastic pneumatic actuator. Maximum permissible viscosity 600 mm/s (cSt). GEMU ludion flowmeter - Polyamide - DN20 threaded - from 15 to 160 l/h - Pmax: 10 bar - (+)60☌. The valve spindle is sealed by a self-adjusting gland packing or a compact seal cartridge, dependent on the size and version. A wiper ring or the wiper contour of the seal cartridge additionally protects the valve spindle against contamination and damage thus providing low maintenance and reliable valve spindle sealing, even after a long service life. Meter valves are larger, of heavier construction and the needle has a rounded end. Suitable for inert and corrosive* liquid and gaseous media. Micro Motion Fork Viscosity Meters are accurate multi-variable devices that measure liquid viscosity, density and temperatureunder demanding conditions.Maximum permissible viscosity 600 mm²/s (cSt).Cast Stainless Steel body, available in sizes: 3/8" to 2 1/2".Cast Bronze body, available in sizes: 1/2" up to 3".Flow orientation options: Flow Below Seat (for liquid and gas) or Flow Above Seat (for steam and gas).GEMU GEMU GebrOder M011erApparatebau GmbH & Co. Maximum permissible temperature of control medium: 60 ☌. These meters use vibrating fork technology to provide reliable direct insertion measurement. ![]() *Working medium: Corrosive, inert, gaseous and liquid media which have no negative impact on the physical and chemical properties of the body and PTFE seal material.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |